Main SP Tables-1
D146/D147/D148/D149/D150 2-24 System Maintenance Section
031
Temp.:Lower Delta:Press *ENG
[0 to 200 / D146:11, D147:11,
D148:5, D149:11, D150:11 /
1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
pressure
032
Temp.:Lower Delta:Press *ENG
[0 to 200 / D146:28, D147:28,
D148:22, D149:28, D150:28 /
1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
pressure
033
Rotation Time *ENG [0 to 100 / 0 / 1sec/step]
Do not change. Paper feed start permission temp. : before decision rotate time
034
Temp.:Lower Delta:Center *ENG [0 to 200 / 5 / 1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
center
035
Temp.:Lower Delta:End *ENG [0 to 200 / 5 / 1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
edge
036
Temp.:Upper Delta:Center *ENG [0 to 200 / 15 / 1deg/step]
Do not change. Paper feed start permission temp. upper diff from target temp. :
center
037
Temp.:Upper Delta:End *ENG [0 to 200 / 15 / 1deg/step]
Do not change. Paper feed start permission temp. upper diff from target temp. :
edge
038
Temp.:Lower Delta:Press *ENG [0 to 200 / 100 / 1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
pressure
039
Temp.:Lower Delta:Press *ENG [0 to 200 / 15 / 1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
pressure