Main SP Tables-1
D146/D147/D148/D149/D150 2-26 System Maintenance Section
046
Temp.:Lower
Delta:Press:Power A
*ENG
[0 to 200 / D146, D147:77, D148:
71, D149:NA TW: 37, D149(EU,
AS, CHN, KOR): 63, D150(NA,
TW): 25, D150(EU, AS, CHN,
KOR): 45 / 1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
pressure
047
Rotation Time:Power A *ENG [0 to 100 / 0 / 1sec/step]
Do not change. Paper feed start permission temp. : before decision rotate time
051
Judgment Power B *ENG
[0 to 2000 / D146(NA, TW): 1320,
D146(EU, AS, CHN, KOR): 1430,
D147(NA, TW): 1315, D147(EU,
AS, CHN, KOR):1425, D148(NA,
TW): 1270, D148(EU, AS, CHN,
KOR): 1530, D149(NA, TW): 1225,
D149(EU, AS, CHN, KOR): 1485,
D150(NA, TW): 1215, D150(EU,
AS, CHN, KOR): 1475 / 1W/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
center
052
Temp.:Lower
Delta:Center:Power B
*ENG
[0 to 200 / D146:40, D147:40,
D148:52, D149:40, D150:40 /
1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
center: special mode 1
053
Temp.:Lower
Delta:End:Power B
*ENG
[0 to 200 / D146:40, D147:40,
D148:52, D149:40, D150:40 /
1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
edge: special mode 1
054
Temp.:Upper
Delta:Center:Power B
*ENG [0 to 200 / 30 / 1deg/step]