Main SP Tables-1
System Maintenance Section 2-33 D146/D147/D148/D149/D150
034
Special2:FC:Press *ENG
[0 to 200 / D146:118, D147:118,
D148:118, D149:143, D150:143 /
1deg/step]
Do not change. paper through target temperature: special paper 2: FC:
pressure
035
Special2:BW:Center *ENG
[100 to 180 / D146:139, D147:139,
D148:141, D149:157, D150:157 /
1deg/step]
Paper through target temperature: special paper 2: BW: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
036
Special2:BW:Press *ENG
[0 to 200 / D146:118, D147:118,
D148:118, D149:137, D150:137 /
1deg/step]
Do not change. paper through target temperature: special paper 2: BW:
pressure
037
Special3:FC:Center *ENG
[100 to 180 / D146:139, D147:139,
D148:141, D149:157, D150:157 /
1deg/step]
paper through target temperature: special paper 3: FC: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
038
Special3:FC:Press *ENG
[0 to 200 / D146:118, D147:118,
D148:118, D149:137, D150:137 /
1deg/step]
Do not change. paper through target temperature: special paper 3: FC:
pressure
039 Special3:BW:Center *ENG
[100 to 180 / D146:139, D147:139,
D148:141, D149:157, D150:157 /
1deg/step]