Main SP Tables-1
System Maintenance Section 2-41 D146/D147/D148/D149/D150
Paper through target temperature: envelope: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
134
Envelop:Press:Low Speed *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: envelope: pressure: low
speed
135
Thin:FC:Center:Low Speed *ENG [100 to 180 / 110 / 1deg/step]
Paper through target temperature: thin paper: FC: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
136
Thin:FC:Press:Low Speed *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: thin paper: FC: pressure: low
speed
137
Thin:BW:Center:Low Speed *ENG [100 to 180 / 110 / 1deg/step]
Paper through target temperature: thin paper: BW: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
138
Thin:BW:Press:Low Speed *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: thin paper: BW: pressure:
low speed
139
Thick4:FC:Center *ENG [100 to 180 / 147 / 1deg/step]
Paper through target temperature: thick paper 4: FC: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
140
Thick4:FC:Press *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: thick paper 4: FC: pressure
141 Thick4:BW:Center *ENG [100 to 180 / 147 / 1deg/step]