Main SP Tables-1
D146/D147/D148/D149/D150 2-126 System Maintenance Section
006
Feed CCW:Thick 2:Low *ENG [-2.0 to 2.0 / 1.2 / 0.1%/step]
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
image position accuracy improve. Reflect adjusted value as they are Metis-C1
all: 73mm/s
007
Feed CCW:Thick 3:Low *ENG [-2.0 to 2.0 / 0.9 / 0.1%/step]
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
image position accuracy improve. Reflect adjusted value as they are Metis-C1
all: 73mm/s
008
Feed CCW:Thick 4:Low *ENG [-2.0 to 2.0 / 0.9 / 0.1%/step]
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
image position accuracy improve. Reflect adjusted value as they are Metis-C1
all: 73mm/s
009
Feed CW:Plain:Low *ENG [-2.0 to 2.0 / 0.9 / 0.1%/step]
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
image position accuracy improve. Reflects adjusted value as they are. All:
73mm/s, 1200dpi mode
010
Feed CW:Plain:Std *ENG [-2.0 to 2.0 / 0.9 / 0.1%/step]
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
image position accuracy improve. Reflect adjusted value as they are
Metis-C1a: 146mm/s, Metis-C1b: 146mm/s, Metis-C1c: 186mm/s, Metis-C1d:
256mm/s, Metis-C1e: 256mm/s
011
Feed CW:Mid-thick:Std *ENG [-2.0 to 2.0 / 1.1 / 0.1%/step]
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
image position accuracy improve. Reflect adjusted value as they are
Metis-C1a: 146mm/s, Metis-C1b: 146mm/s, Metis-C1c: 186mm/s, Metis-C1d:
256mm/s, Metis-C1e: 256mm/s
012
Feed CW:Thick 1:Low *ENG [-2.0 to 2.0 / 1.2 / 0.1%/step]
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
image position accuracy improve. Reflect adjusted value as they are
Metis-C1a: 73mm/s, Metis-C1b: 73mm/s