10.15 LEAD EDGE ERASE MARGIN ADJUSTMENT (SP2-101-001)
When: If the lead edge erase margin is not within the
adjustment standard.
Purpose: To maintain a proper lead edge erase margin.
Adjustment Standard:
2.5 ± 1.5 mm (0.1 ± 0.06")
How: SP2-101-001 changes the erase lamp off timing.
SP2-101-001: Lead Edge Erase
0 - 32 (default = 16, – 8.0 mm to + 8.0 mm), 0.5 mm per step
10.16 LENS HORIZONTAL H.P. ADJUSTMENT (SP4-011-001~009)
When: If side-to-side registration is not within the
adjustment standard.
Purpose: To maintain proper side-to-side registration from all
feed stations.
Adjustment standard:
0 ± 2 mm (0 ± 0.08")
How: SP4-011-001~009 changes the lens horizontal home
position.
SP4-011-001~007 and 009 change the lens
horizontal home position used for certain units (see
step 3 below). If registration is not within the
standard when using a certain unit, use one of these
SP modes.
SP4-011-008 is the base adjustment made in the
factory. If this setting is changed by a small amount,
all other SP4-011 settings change automatically by
the same amount. Use this if the image shift
direction (to the front or to the rear) is the same from
all paper feed stations.
1. Make a full size copy from each paper feed station.
2. Check whether side-to-side registration is within the adjustment standard.
Rev. 7/95
FSM 5-63 FT5535/4527/4522