4. Refer to the "SP MODE FACTORY SETTING DATA" sheet located in the
upper inner cover and enter the data that were stored in the following SP
modes at the factory.
• SP1-001: Registration Adjustment
• SP2-001: Drum Charge Roller Voltage (for Copying)
• SP2-003: Drum Charge Roller Voltage (for VSP Pattern)
• SP2-101-001: Lead Edge Erase Margin
• SP4-001: Exposure Lamp Voltage Adjustment
• SP4-008: Vertical Magnification Adjustment
• SP4-011-008: Base Horizontal H.P. Adjustment
• SP4-101: Horizontal Magnification Adjustment
• SP4-102: Lens Error Correction
• SP4-103: Focus Adjustment
5. Perform the following SP modes in the following order (see "Practical SP
Mode Use Tables" for details):
(1) SP2-214: TD Sensor Initial Setting
(2) SP3-123: Drum Initialization
(3) SP3-001: ID Sensor Initial Setting
(4) SP3-112: Forced VR Detection
(5) SP4-001: Exposure Lamp Voltage Adjustment
(6) SP4-201: Auto ADS Gain Adjustment
(7) SP3-105: Forced VL Detection
6. Check the copy quality and the paper path and do any necessary
adjustments (see Replacement and Adjustment - Copy Quality Adjustments).
FSM 4-13 FT5535/4527/4522