Slide 128
Energy Save Effectiveness - 2/3
(1) At start of measurement period, read values of SP
8941:001-005 (Machine Status).
(2) At end of measurement period, read values of SP
8941:001-005 (Machine Status).
(3) Find amount of time spent in each mode.
(Subtract earlier measurement from later measurement
and convert result to hours. )
(4) Power consumption figures for each model are acquired
from “Publication System of MSDS_&_PEI (PRODUCT
ENVIRONMENT INFORMATION)” database.
Example:
7WOff/Sleep mode
214WReady mode / Energy Save
1081.8WOperating mode
Power consumption:Mode/condition