Energy Save Effectiveness - 3/3
(5) Multiply this by power consumption spec for each mode and
convert result to kWh (kilowatt hours)
(6) This is a simulated value for power consumed.
Example calculations:
Mode
/condition
SP8941:
Machine Status
Time
at Start
(min.)
Time
at End
(min)
Running
time (hour)
(
②-①
)/60
=③
Power
Consumption
Spec.(W)
Power
consumption
.(KWH)
(
③x④
)/1000
=⑤
Operating 001:
Operating
Time
21089 21386 5.0 1081.8 5.35
Stand by
(Ready)
002:
Standby Time
306163 308046 31.4 214.0 6.72
Energy save 003
Energy Save Time
71386 75111 62.1 214.0 13.29
Off/Sleep 005:
Off mode Time
508776 520377 193.4 7.0 1.35
Total
26.71