001
Mode Selection *ENG
[0 to 3 / 1 / 1/step]
0:do not adjust SSCG
1: Only adjust analog.(default)
2: Only adjust digital
3: Adjust both analog/digital.
Selects SSCG Noise Correction Mode.
Use when SSCG does not function correctly due to accidental malfunction, as a temporally
action, set with out adjusting SSCG.
When SSCG does not function correctly, due to scanner, side streak/cross streak might
appear in high density area.
Use this temporally if changing setting redresses problem.
4637 [SSCG Noise Cancel (Analog)]
001
Latest:F:RE ENG [-31 to 31 / 0 / 1digit/step]
Displays SSCG analog correction value (F Side/RED/EVEN pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
002
Latest:F:RO ENG [-31 to 31 / 0 / 1digit/step]
Displays SSCG analog correction value (F Side/RED/ODD pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
003
Latest:F:GE ENG [-31 to 31 / 0 / 1digit/step]
Displays SSCG analog correction value (F Side/GREEN/EVEN pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
004
Latest:F:GO ENG [-31 to 31 / 0 / 1digit/step]
Displays SSCG analog correction value (F Side/GREEN/ODD pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).