006
Latest:F:BO *ENG [-255 to 255 / 0 / 1digit/step]
Displays SSCG Digital correction value (F Side/BLUE/ODD pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
007
Latest:L:RE *ENG [-255 to 255 / 0 / 1digit/step]
Displays SSCG Digital correction value (L Side/RED/EVEN pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
008
Latest:L:RO *ENG [-255 to 255 / 0 / 1digit/step]
Displays SSCG Digital correction value (L Side/RED/ODD pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
009
Latest:L:GE *ENG [-255 to 255 / 0 / 1digit/step]
Displays SSCG Digital correction value (L Side/GREEN/EVEN pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
010
Latest:L:GO *ENG [-255 to 255 / 0 / 1digit/step]
Displays SSCG Digital correction value (L Side/GREEN/ODD pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
011
Latest:L:BE *ENG [-255 to 255 / 0 / 1digit/step]
Displays SSCG Digital correction value (L Side/BLUE/EVEN pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
012
Latest:L:BO *ENG [-255 to 255 / 0 / 1digit/step]
Displays SSCG Digital correction value (L Side/BLUE/ODD pixel).
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
SP4-XXX (Scanner)