4639 [SSCG Noise Cancel (Analog)]
001
Factory :F:RE *ENG [-31 to 31 / 0 / 1digit/step]
Display/Saves Factory SSCG Analog correction value (F Side/RED/EVEN pixel).
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
002
Factory :F:RO *ENG [-31 to 31 / 0 / 1digit/step]
Display/Saves Factory SSCG Analog correction value (F Side/RED/ODD pixel).
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
003
Factory :F:GE *ENG [-31 to 31 / 0 / 1digit/step]
Display/Saves Factory SSCG Analog correction value (F Side/GREEN/EVEN pixel).
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
004
Factory :F:GO *ENG [-31 to 31 / 0 / 1digit/step]
Display/Saves Factory SSCG Analog correction value (F Side/GREEN/ODD pixel).
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
005
Factory :F:BE *ENG [-31 to 31 / 0 / 1digit/step]
Display/Saves Factory SSCG Analog correction value (F Side/BLUE/EVEN pixel).
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
006
Factory :F:BO *ENG [-31 to 31 / 0 / 1digit/step]
Display/Saves Factory SSCG Analog correction value (F Side/BLUE/ODD pixel).
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
007
Factory :L:RE *ENG [-31 to 31 / 0 / 1digit/step]
Display/Saves Factory SSCG Analog correction value (L Side/RED/EVEN pixel).
Adjusted SSCG correction Value during the main unit warranty process is saved.
Use for analyzing malfunction, comparing factory / current value.
2. Main SP Tables-4