001
Original Density Thresh *ENG [0 to 255 / 18 / 1digit/step]
Sets scan image density Thresh for Scan size detection.
002
Detection Time *ENG [20 to 100 / 60 / 20msec/step]
Sets Detection time for scan size detection.
003
Lamp ON:Delay Time *ENG [40 to 200 / 40 / 10msec/step]
Adjusts lamp light timing for scan size detection.
004
LED PWM Duty *ENG [0 to 100 / 60 / 1/step]
Adjusts light value for scan size detection.
4310
[Scan Size Detect Value]
Checks the density of scanning data for the scan size detection.
001 S1:R ENG [0 to 255 / 0 / 1digit/step]
002 S1:G ENG [0 to 255 / 0 / 1digit/step]
003 S1:B ENG [0 to 255 / 0 / 1digit/step]
004 S2:R ENG [0 to 255 / 0 / 1digit/step]
005 S2:G ENG [0 to 255 / 0 / 1digit/step]
006 S2:B ENG [0 to 255 / 0 / 1digit/step]
007 S3:R ENG [0 to 255 / 0 / 1digit/step]
008 S3:G ENG [0 to 255 / 0 / 1digit/step]
009 S3:B ENG [0 to 255 / 0 / 1digit/step]
4350 [Intermittent Shading : BW]
001
Switch On/Off ENG
[0 or 1 / 1 / 1/step]
1: Intermittent Shading ON
0: Intermittent Shading OFF(Shad
every time)
Switches On/OFF for Intermittent Shading when scanning BW (Simplex/Duplex).
SP4-XXX (Scanner)