003
Factory Set:L:BE *ENG [0 to 127 / 0 / 1digit/step]
Display/Saves Factory Black level analog adjusting value (L side/BLUE/EVEN Pixel)
Factory Black level analog adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
004
Factory Set:L:BO *ENG [0 to 127 / 0 / 1digit/step]
Display/Saves Factory Black level analog adjusting value (L side/BLUE/ODD Pixel)
Factory Black level analog adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4673 [Black Level Adj Value(Digital)]
001
Factory :F:RE *ENG [0 to 16383 / 0 / 1digit/step]
Display/Saves Factory Black level digital adjusting value (F side/RED/EVEN Pixel)
Factory Black level digital adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
002
Factory :F:RO *ENG [0 to 16383 / 0 / 1digit/step]
Display/Saves Factory Black level digital adjusting value (F side/RED/ODD Pixel)
Factory Black level digital adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
003
Factory :L:RE *ENG [0 to 16383 / 0 / 1digit/step]
Display/Saves Factory Black level digital adjusting value (L side/RED/EVEN Pixel)
Factory Black level digital adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
004
Factory :L:RO *ENG [0 to 16383 / 0 / 1digit/step]
Display/Saves Factory Black level digital adjusting value (L side/RED/ODD Pixel)
Factory Black level digital adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4674 [Black Level Adj Value(Digital)]
2. Main SP Tables-4