004
L:BO ENG [0 to 1023 / 0 / 1digit/step]
Displays Black level peek scanning value (L side/BLUE/ODD Pixel).
Image signal’s offset level will be checked and given when Scanner turns on and the Black
level is checked.
Confirming if SBU‘s (SCAT) offset adjusting function is running normal.
When Black level peak scanning value is abnormal, SC141-00 is given.
Cause of error will show in SP4-646-005.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4699 [SBU Test Pattern Change]
001
- ENG
[0 to 255 / 0 / 1/step]
0: Normal image output, SH/Black
reduce: Not set (default)
1: test pattern output, Output fixed
value(682digit), SH/Black reduce:
OFF
2: Test pattern output, Main scan
gradation pattern(10bit tone, 4dot
step), SH/Black reduce: OFF
3:Test pattern output, Main scan
gradation pattern (10bit tone, 3line
step), SH/Black reduce: OFF
4:Test pattern output, grid pattern
(20mm x 10mm grid pattern), SH/
Black reduce: OFF
Outputs SBU Test pattern.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4700 [CIS ID Display]
001
- ENG [0x00 to 0xFF / 0 / 1/step]
When CIS’s ID is not normal, cause flag is set to SP4-747-001 and becomes SC185-00.
4712 [CIS GB Adj Value: R]
SP4-XXX (Scanner)
163