4798 [CIS LED Duty]
001
CIS LED Duty *ENG [0 to 65535 / 0 / 1/step]
Display/Saves LED lighting duty for CIS.
Value set when shipping test for CIS is saved.
Normally won’t change this setting.
4799 [CIS TEST Pattern]
001
Select ENG
[0 to 5 / 0 / 1/step]
0: Scanned Image
1: Fixed Value Pattern
2: EO Fixed Value Pattern
3: Main Scan Gradation
4: Sub Scan Gradation
5: Grid Pattern
Sets output test pattern for CIS.
When printing out test pattern set with this SP,
Press copy button after setting, exit with break key and set paper size, scale, image process
conditions as a regular copy, and Set original.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
002
Even Output Level Setting ENG [0 to 4095 / 0 / 1digit/step]
Sets fixed value output level (Even) of test pattern for CIS.
Fixed value will be display/set when SP4-799-001-1: full side fixed value, or
SP4-799-001-2: fixed value for each EO is selected.
003
Odd Output Level Setting ENG [0 to 4095 / 0 / 1digit/step]
Sets fixed value output level (Odd) of test pattern for CIS.
Fixed value will be display/set when SP4-799-001-1: full side fixed value, or
SP4-799-001-2: fixed value for each EO is selected.
4813 [ALC Selection]