004
Environ:Recent *ENG [- / - / -]
Displays the current environment according to the absolute humidity calculated by
Temperature/Humidity Sensor (Main Unit).
005
Environ:Recent 2 ENG [- / - / -]
Displays the current environment according to the absolute humidity calculated by
Temperature/Humidity Sensor (Main Unit).
3262 [Env Set:PCU]
001
Force Settings ENG
[0 to 6 / 0 / 1/step]
0: Sensor Detection, 2-6: Each
Environment for LL-HH
Forced setting for PCU Environment
3263 [Env Set:Body]
001
Force Settings ENG
[0 to 6 / 0 / 1/step]
0: Sensor Detection, 1-6: Each
Environment for LLL-HH
Sets forcibly the current environment (Main Unit)
003
Force Settings 2 ENG
[0 to 10 / 0 / 1/step]
0: Sensor Detection, 1-10: Each
Environment for 1-10
Sets forcibly the current environment (Main Unit 2)
3264
[Env Thresh:PCU]
Threshold for Environment Division
002 Abs Humid:2 *ENG
[0.00 to 100.00 / 5.00 / 0.01g/m3/
step]
003 Abs Humid:3 *ENG
[0.00 to 100.00 / 10.00 /
0.01g/m3/step]
004 Abs Humid:4 *ENG
[0.00 to 100.00 / 18.00 /
0.01g/m3/step]
SP3-XXX (Process)
25