011
M/A(Target):K *ENG
[0.000 to 1.000 / 0.150 /
0.001mg/cm2/step]
Displays ID Pattern Target M/A (K).
012
M/A(Target):C *ENG
[0.000 to 1.000 / 0.433 /
0.001mg/cm2/step]
Displays ID Pattern Target M/A (C).
013
M/A(Target):M *ENG
[0.000 to 1.000 / 0.433 /
0.001mg/cm2/step]
Displays ID Pattern Target M/A (M).
014
M/A(Target):Y *ENG
[0.000 to 1.000 / 0.433 /
0.001mg/cm2/step]
Displays ID Pattern Target M/A (Y).
021
M/A(Corr):K *ENG
[-0.150 to 0.150 / 0.000 /
0.001mg/cm2/step]
Corrects ID Pattern M/A (K) based on P_Rank if Development gamma is out of the target
value.
022
M/A(Corr):C *ENG
[-0.150 to 0.150 / 0.000 /
0.001mg/cm2/step]
Corrects ID Pattern M/A (C) based on P_Rank if Development gamma is out of the target
value.
023
M/A(Corr):M *ENG
[-0.150 to 0.150 / 0.000 /
0.001mg/cm2/step]
Corrects ID Pattern M/A (M) based on P_Rank if Development gamma is out of the target
value.
024
M/A(Corr):Y *ENG
[-0.150 to 0.150 / 0.000 /
0.001mg/cm2/step]
Corrects ID Pattern M/A (Y) based on P_Rank if Development gamma is out of the target
value.
101
M/A(Latest):K *ENG
[0.000 to 1.000 / 0.000 /
0.001mg/cm2/step]
Displays the latest ID Pattern M/A (K).
SP3-XXX (Process)