021
M/A UppErr:K ENG
[0.000 to 1.000 / 0.600 /
0.001mg/cm2/step]
Sets Error Judgment Threshold (K) for SC380 ID Pattern Error.
022
M/A UppErr:Col ENG
[0.000 to 2.000 / 1.200 /
0.001mg/cm2/step]
Sets Error Judgment Threshold (CMY) for SC381-SC383 ID Pattern Error.
023
M/A LowErr:K ENG
[0.000 to 1.000 / 0.100 /
0.001mg/cm2/step]
Sets Error Judgment Threshold (K) for SC385 ID Pattern Error.
024 M/A LowErr:Col ENG
[0.000 to 1.000 / 0.200 /
0.001mg/cm2/step]
Sets Error Judgment Threshold (CMY) for SC386-SC388 ID Pattern Error.
031
Feed Cnt :Set *ENG
[0 to 99999999 / 50000 / 1msec/
step]
Totals ON Time for Feed Clutch of Sub Hopper. (Resets if Toner End Sensor detects Yes.)
041
Feed Cnt :K *ENG [0 to 99999999 / 0 / 1msec/step]
Totals ON Time for Feed Clutch (K) of Sub Hopper.
042
Feed Cnt :C *ENG [0 to 99999999 / 0 / 1msec/step]
Totals ON Time for Feed Clutch (C) of Sub Hopper.
043
Feed Cnt :M *ENG [0 to 99999999 / 0 / 1msec/step]
Totals ON Time for Feed Clutch (M) of Sub Hopper.
044
Feed Cnt :Y *ENG [0 to 99999999 / 0 / 1msec/step]
Totals ON Time for Feed Clutch (Y) of Sub Hopper.
3310 [ID.Sens :Voffset]
001
Voffset_reg *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Displays Regular Reflection Output Voltage when ID Sensor LED is turned off.
SP3-XXX (Process)
29