5. Main SP Tables-7
SP7-001 to 931 (Data Log)
7001
[Engine Drive Distance Counter]
Displays Engine Drive Distance Counter.
001 #PCU:K ENG [0 to 99999999 / 0 / 1m/step]
7401
[Total SC]
Stores total SC occurring count.
If the same SC codes are detected continuously and total counter is not increasing, it only
logs once in case of deleting other SC code logs.
001 SC Counter *CTL [0 to 65535 / - / 1/step]
002 Total SC Counter *CTL [0 to 65535 / - / 1/step]
7403
[SC History]
Logs and displays the SC codes detected.
The 10 most recently detected SC Codes are displayed on the screen, and also can be
seen on the SMC (logging) outputs.
If the same SC codes are detected continuously and total counter is not increasing, it
only logs once in case of deleting other SC code logs.