248
Decurl Transfer STM:MidLow Spd
*D136 only
ENG
[0 or 1 / 0 / 1/step]
1: ON (Active)
0: OFF (Stop)
This SP is only for D136 machine. Executing this SP on D135/D137/D138 machines may
cause SC error.
Beware that long hours of operation may occur breakdown.
249
Decurl Transfer STM:Low Spd ENG
[0 or 1 / 0 / 1/step]
1: ON (Active)
0: OFF (Stop)
Beware that long hours of operation may occur breakdown.
250 Decurler:Press Motor ENG [0 or 1 / 0 / 1/step]
6012 [1-Pass ADF OUTPUT Check]
001
Pick-Up Motor Forward ENG
[0 or 1 / 0 / 1/step]
0:Off
1:On
Executes driving ADF Pick-Up Motor forward.
003
Feed Motor Forward ENG
[0 or 1 / 0 / 1/step]
0:Off
1:On
Executes driving ADF Feed Motor forward.
005
Relay Motor Forward ENG
[0 or 1 / 0 / 1/step]
0:Off
1:On
Executes driving ADF Relay Motor forward.
009
Exit Motor Forward ENG
[0 or 1 / 0 / 1/step]
0:Off
1:On
Executes driving ADF Exit Motor forward.
Output Check Table