022
Return TransM:Cont ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Return Transport Motor (Continuous operation)
023
Shift Jog Moter:1 Op ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Shift Jogger Motor (One operation)
024
Shift Jog Shunt Moter:1 Op ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Shift Jogger Shunt Motor (One operation)
025
Top Fence Motor:1 Op ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Top Fence Motor (One operation)
026
Bottom Fence Motor:1 Op ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Bottom Fence Motor (One operation)
027
Lower Transport Mtr:Cont ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Lower Transport Motor (Continuous operation)
028
Upper Tray Exit Mtr:Cont ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Upper Tray Exit Motor (Continuous operation)
029
Positioning Roller Mtr:Cont ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Positioning Roller Motor (Continuous operation)
030
Prestack Trans Mtr:Cont ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Prestack Transport Motor (Continuous operation)
031
Staple Trim Chute SOL:1 Op ENG [0 or 1 / 0 / 1/step]
OUTPUT Check for Staple Trim Chute SOL (One operation)
6161 [OUTPUT Check Print Post]
001
Vert Transport Motor ENG [0 or 1 / 0 / 1/step]
Drives Transport Motor continuously for operation check.
002
Junction Gate SOL1 ENG [0 or 1 / 0 / 1/step]
Turns the specified Solenoid ON/OFF for operation check.
Output Check Table