Technical Bulletin PAGE: 2/8
Model: Vacuum Feed LCIT RT5100
Date: 3-Aug-16
No.: RD777009
4. Measure the distance (span) between the two side plates (Fig. 2).
Important: The scale ends should touch the bent portion of the side plates.
Fig. 2
5. Take the same measurement with the tray in the middle and lower positions (Fig. 3).
Fig. 3
6. Measure the clearance between the bent portion of the side plate and the bearing
flange.
Important: To do this, shift the bottom plate toward the rear side (Fig. 4).