Technical Bulletin  PAGE: 8/13 
Reissued: 17-Jan-17 
Model: Vacuum Feed LCIT RT5100 
 
NOTE: Step 3-2 and 3-3 have been added. 
 
3-2 Remove the plates [A] (if installed) and [B] – (See step 3-3) 
 
 [A] 
 
 
 
 
                 [B] 
 
 
 
 
 
 
 
 
3-3. To remove plates [B] gently skew the plate as indicated in the picture below.  
Some force is required. 
 
 
Remark: When re-installing be sure to hook part [A] under the bottom plate. 
 
 
            [A]