Technical Bulletin PAGE: 2/2
Model: Vacuum Feed LCIT RT5100 Date: 12-Sep-19 No.: RD777018
2. Paste the Mylar to the feeler.
IMPORTANT:
Paste it so that it does not extend beyond the edge [a] of the feeler. The detection timing
may be change, which may cause other trouble.
Does not use transparent Mylar.
Adjust the length [b] according to the gap [c] of the actual machine.
3. Attach the feeler in the reverse order and check the following to confirm the effectiveness:
- Whether the SC recurs by lifting the tray
- Whether Mylar is interfering with other parts during lifting
- Whether there is any indication that the Mylar has hit/contacted something
- Whether the bottom plate is inclined