Paper Skew Correction (Sub Scan)
LCIT
When the leading edge [8]
activates the registration
timing sensor [3], the LCIT
exit roller lift motor [9] turns
on.
This lowers the exit idle roller
[10] to release the paper so
that it can strike the
registration gate.
At the same time, inside the
machine, the LCT relay roller
solenoid [11] raises the LCT
relay roller to release the
paper at the machine
entrance.
All skew and paper position correction is done by the registration unit in the main
machine.
There is no mechanism in the LCIT to correct the paper position in either the sub
scan direction (right-to-left) or the main scan direction (front-to-rear).
¾ Some older LCITs have a CIS mechanism for registration correction. This