Taurus-C1 Training
61
Slide 61
Image Transfer Unit (1)
 Two motors raise and lower the ITB. One motor operates the left
tray (contains the components for YMC) and one motor operates
the right tray (K).
 The belt centering sensor for this machine is simpler than the
D016.
 The sensor, a small CIS, (shown below with the ITB removed) is
mounted below the rear edge of the belt. It monitors the position of
the belt directly. The pendulum actuator mechanism of the D016
has been eliminated.