Technical information
Maintenance
2
Ridder Drive Systems B.V. T +31 (0)341 416 854 I ridder.com E info@ridder.com
11
Maintenance TU rack drives
Inspection and maintenance work is only permitted to approved personnel.
Installation TU
After installation, lubricate slide bearings of TU rack-drive and slide-bearing plates. Lubrication of
sheet-steel racks is not permitted. Refer to "Lubricate TU".
Maintenance TU
Every 6 months inspection of system and rack drives on technical state (wear and tear, fasteners and
such) and proper functioning. With this the slide bearings of TU rack-drive and slide-bearing plates
have to be lubricated. Lubrication of sheet-steel racks is not permitted. Refer to "Lubricate TU".
Lubricate TU
Lubricate slide bearings all around (fully: between surfaces tube/bearing) of TU rack-drive and slide-
bearing plates with brush.
Lubrication of sheet-steel racks is
not
permitted.
Lubricant TU and slide-bearing plates
Grease: DIVINOL LITHOGREASE 7000 (DLG7) (item number: 182051/ 182056/ 182058)