Model K9-306 FlexShaft
Drain Cleaning Machine
K9-306 Manual
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Other manuals for RIDGID FlexShaft K9-306

Questions and Answers

Summary

Safety Information and Warnings

Safety Symbols Explained

Explains signal words and symbols used in the manual and on the product for clarity.

General Power Tool Safety

Comprehensive safety warnings for power tools, work areas, and personal protection.

Specific Machine Safety Precautions

FlexShaft Drain Cleaning Machine Safety

Critical safety precautions specific to the FlexShaft drain cleaning machine operation.

Specifications and Pre-Operation Checks

Pre-Operation Inspection Procedures

Steps to inspect the machine before use to ensure safety and proper function.

Machine and Work Area Setup

Chain Knocker Installation and Adjustment

Operating the Drain Cleaning Machine

General Operating Instructions

Instructions for safely and effectively operating the drain cleaning machine.

Maintenance and Cable Care

Motor, Troubleshooting, and Overload

Troubleshooting Common Issues

Solutions for common problems encountered with the drain cleaning machine.

Service, Repair, and Options

RIDGID Lifetime Warranty

Summary

Safety Information and Warnings

Safety Symbols Explained

Explains signal words and symbols used in the manual and on the product for clarity.

General Power Tool Safety

Comprehensive safety warnings for power tools, work areas, and personal protection.

Specific Machine Safety Precautions

FlexShaft Drain Cleaning Machine Safety

Critical safety precautions specific to the FlexShaft drain cleaning machine operation.

Specifications and Pre-Operation Checks

Pre-Operation Inspection Procedures

Steps to inspect the machine before use to ensure safety and proper function.

Machine and Work Area Setup

Chain Knocker Installation and Adjustment

Operating the Drain Cleaning Machine

General Operating Instructions

Instructions for safely and effectively operating the drain cleaning machine.

Maintenance and Cable Care

Motor, Troubleshooting, and Overload

Troubleshooting Common Issues

Solutions for common problems encountered with the drain cleaning machine.

Service, Repair, and Options

RIDGID Lifetime Warranty

Overview

The RIDGID K9-306 FlexShaft™ Drain Cleaning Machine is a robust and versatile tool designed for cleaning and descaling drain lines and pipes. It is engineered for professional use in plumbing and drain maintenance, offering a blend of power, flexibility, and safety features.

Function Description:

The K9-306 FlexShaft Drain Cleaning Machine is primarily used to clear blockages and descale the internal walls of pipes. It operates by rotating a chain knocker at high speeds (up to 2000 RPM) within the drain. The cable assembly, which includes the chain knocker, is manually fed into and out of the drain. The machine utilizes a low-torque, high-speed approach, allowing the chain knocker to effectively break up blockages and clean pipe walls without excessive force. This method is particularly suitable for use with inspection cameras, enabling operators to monitor the cleaning process in real-time. The machine is designed to be user-friendly, with controls for cable rotation (REV/O-OFF/FOR switch) and motor activation (pneumatic foot switch). An integrated Ground Fault Circuit Interrupter (GFCI) in the line cord enhances electrical safety. The machine's design emphasizes control and safety, requiring the operator to maintain a hand on the cable assembly while it is running and to position the machine close to the drain inlet to prevent cable twisting or kinking.

Important Technical Specifications:

  • Model: K9-306 FlexShaft™ Drain Cleaning Machine
  • Drain Capacity (Nominal): 3" to 6" (75 - 150 mm) pipes and drain lines
  • Cable Diameter (without Sheath): 3/8" (9.5 mm)
  • Cable Assembly Diameter (with Sheath): 5/8" (15.9 mm)
  • Cable Assembly Length: 125' (38.1 m)
  • Motor Power: 1.1 kW (1.5 HP)
  • Voltage: 110-120V (11A) or 220-240V (8A)
  • Rotational Speed: 2000 RPM
  • Weight: 166 lbs (75 kg)
  • Dimensions (Handle down): 36.1" x 32.5" x 20.5" (918 mm x 826 mm x 521 mm)
  • Operating Temperature: 20°F to 140°F (-6°C to 60°C)
  • Sound Pressure (LPA): 96.1 dB(A), K=3
  • Sound Power (LPW): 91.8 dB(A), K=3
  • Standard Equipment: Includes various chain knockers for different pipe sizes and blockage types. Carbide-tipped chain knockers are available for aggressive cleaning and root removal, while plain chain knockers are for general use, including grease. Penetrating head chain knockers are also available.
  • Safety Features: Integral GFCI, thermal overload protection for the motor, and specific warnings regarding electrical shock, twisted/broken cables, chemical burns, and infections.

Usage Features:

  • Versatile Cleaning: Capable of cleaning and descaling pipes from 3 to 6 inches in diameter and up to 125 feet in length.
  • Chain Knocker System: Utilizes various chain knockers, including carbide-tipped options for tough blockages like roots and scale, and plain chain knockers for grease and general cleaning. The collar distance of the chain knocker can be adjusted to optimize cleaning for different pipe diameters and to navigate bends.
  • FlexShaft Lubricant: RIDGID FlexShaft lubricant can be applied to the cable sheath to facilitate smoother advancement into the drain, especially over longer distances.
  • Camera Compatibility: Well-suited for simultaneous use with inspection cameras, allowing for visual monitoring of the cleaning process and drain condition. This helps in identifying crossbores, damaged drains, or other utilities to prevent accidental contact and damage.
  • Foot Switch Control: A pneumatic foot switch provides convenient ON/OFF control of the motor, allowing the operator to focus on cable management.
  • REV/O-OFF/FOR Switch: A three-position switch controls the direction of cable rotation (forward, off, reverse), aiding in working through blockages and retrieving the cable.
  • Adjustable Handle: Features a telescoping handle for easy transport and maneuverability, with handle latches to secure it in position.
  • Loading Wheels and Handles: Equipped with loading wheels and handles to assist in lifting and transporting the machine, particularly when loading onto a vehicle.
  • Drain Plug: A drain plug allows for easy draining of the drum after use, preventing water accumulation.

Maintenance Features:

  • Pre-Operation Inspection: Regular inspection before each use is crucial. This includes checking the power cord, GFCI, plug for damage, and ensuring the machine and controls are clean. The cable assembly, sheath, and chain knockers should be inspected for wear, damage, or proper setup.
  • Cleaning: The machine and cable assembly should be cleaned as needed with hot soapy water and/or mild disinfectants. It's important to wipe dirt and debris from the cable sheath as it's retrieved to keep the drum clean and prevent sticking. The machine should not be submerged or flushed with water to avoid damage to electrical components.
  • Lubrication: The FlexShaft Drain Cleaning Machines are factory-lubricated for life, requiring no additional lubrication from the user.
  • Cable Re-termination/Replacement: The FlexShaft cable cannot be shortened or re-terminated; a damaged cable assembly must be replaced entirely. Instructions are provided for removing and installing a new cable assembly, including proper setup of the chain knocker, collar spacer, and knocker bushing.
  • Motor Brush Inspection/Change: Motor brushes should be inspected every 6 months and replaced if they are shorter than 1/2" (13 mm). Instructions are provided for accessing and replacing the brushes.
  • Motor Thermal Overload Reset: The motor is equipped with a thermal overload that automatically shuts off the motor if it overheats. To reset, the machine must be unplugged, the REV/O-OFF/FOR switch set to OFF, allowed to cool for 15 minutes, and then the reset button on the front cover pressed.
  • Troubleshooting Guide: A comprehensive troubleshooting table helps identify common issues (e.g., cable kinking, GFCI tripping, motor not turning on) and provides corresponding solutions.
  • Service and Repair: For issues not covered by the maintenance instructions, the machine should be serviced by a RIDGID Authorized Independent Service Center using only RIDGID service parts.
  • Disposal: Components of the tool are recyclable, and disposal should comply with local waste management regulations, particularly for electrical equipment in EC countries.