EasyManua.ls Logo

Riello 40 F10 - Electrical Wiring

Riello 40 F10
44 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2094
5
GB
ELECTRICAL WIRING
Brown
White
(50V)
Blue
Motor
Capacitor
Regulating thermostat
Neutral
Main switch
T6A
N L
M
~
S7029
Black
NOTES
Wires of 1,5 mm
2
section.
The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
To remove the control-box from the burner,
loosen screw (A) (see figure) and pull
towards the arrow.
The photoresistance is fitted directly into the con-
trol-box (underneath the ignition-transformer) on
a plug-in support.
TESTING
Check the shut-down of the burner by opening
the thermostats.
CARRIED-OUT IN THE FACTORY
DO NOT EXCHANGE THE
230V ~ 50Hz
NL
Limit thermostat
with manual resetting
Remote lock-out lamp
(230V - 0.5A max.), if required
123456789
Blue
Brown
Terminal block of
control-box 530SE
*
Valve
T
T
RUN OF THE ELECTRICAL CABLE
1 - Grommet N - Neutral
2 - Cable-clamp L - Phase
3 - Terminal block - Burner-earth
D5228
Black
NEUTRAL WITH THE PHASE

Other manuals for Riello 40 F10