Home
Riello
Burner
556T40
Riello 556T40 User Manual
4
of 1
of 1 rating
36 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Installat
ion, use
and maint
enance in
structions
20
06
38
00
(
2)
-
10
/2
01
4
Forced d
raught
gas burn
er
One-stage oper
ation
CODE
MODEL
TYPE
3755616
RIELLO
40 GS2
0
556T1
GB
2
Table of Contents
Default Chapter
3
Table of Contents
3
1 Declarations
5
2 Information and General Warnings
6
Information about the Instruction Manual
6
Introduction
6
General Dangers
6
Other Symbols
6
Delivery of the System and the Instruction Manual
7
Guarantee and Responsibility
7
3 Safety and Prevention
8
Introduction
8
Personnel Training
8
4 Technical Description of the Burner
9
Burner Designation
9
Models Available
9
Burner Categories - Countries of Destination
9
Technical Data
10
Maximum Dimensions
10
Firing Rate
11
Test Boiler
11
Commercial Boilers
11
Correlation between Gas Pressure and Burner Output
11
Burner Description
12
Burner Equipment
12
Control Box (RMG88.62C2)
13
4.11 Air Damper Opening Motor
14
5 Installation
15
Notes on Safety for the Installation
15
Instructions to Avoid Burnout or Bad Combustion of the Burner
15
Handling
15
Preliminary Checks
16
Control of the Supply
16
Control of Burner Characteristics
16
Operating Position
16
Securing the Burner to the Boiler
17
Hinge Installation
17
Positioning the Probe - Electrode
17
Combustion Head Adjustment
18
Air Dampers Adjustment
18
Gas Feeding
19
5.10.1 Gas Feeding Line
19
Gas Train
19
5.10.3 Gas Train Installation
20
Electrical Wiring
21
5.11.1 Notes on Safety for the Electrical Wiring
21
5.11.2 Standard Wiring Diagram
22
Electrical Wiring with Valve Seal Control (DUNGS VPS 504)
23
5.11.4 Ionisation Current
23
6 Start-Up, Calibration and Operation of the Burner
24
Notes on Safety for the First Start-Up
24
Adjustments Prior to Ignition
24
Combustion Adjustment
24
Air Pressure Switch
24
Operation Sequence of the Burner
25
Start-Up Programme Visual Diagnostics
25
Normal Operation / Flame Detection Time
25
7 Maintenance
26
Notes on Safety for the Maintenance
26
Maintenance Programme
26
Maintenance Frequency
26
Checking and Cleaning
26
Opening the Burner
27
8 Faults - Possible Causes - Solutions
28
Tracing the Causes of the Malfunctioning
28
Control Box Reset
28
Visual Diagnostics
28
Software Diagnostics
28
A Appendix - Accessories
32
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Riello 556T40 and is the answer not in the manual?
Ask a question
Riello 556T40 Specifications
General
Model
556T40
Flame Supervision
Ionization Probe
Fuel
Gas
Electrical Supply
230V, 50Hz
Control
Electronic
Ignition
Electronic
Related product manuals
Riello RL 50
40 pages
Riello 568 M
32 pages
Riello RS 50/E
40 pages
Riello RS 50/M MZ
76 pages
Riello RX 500 S/PV
60 pages
Riello 40 F20 1/230/50
44 pages
Riello RDB 3.2 BT 50/70
36 pages
Riello 721 T
20 pages
Riello RS 70
52 pages
Riello RS 100
52 pages
Riello RS 100/M
56 pages
Riello RS 25/M BLU
8 pages