EasyManua.ls Logo

Riello RS 50 User Manual

Riello RS 50
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation, use and maintenance instructions
20144599 (1) - 02/2018
Forced draught gas burners
Progressive two-stage operation
CODE MODEL TYPE
3783302 RS 28 809 T1
3784402 RS 38 810 T1
3784403 RS 38 810 T1
3784502 RS 38 810 T1
3784503 RS 38 810 T1
3784702 RS 50 811 T1
3784703 RS 50 811 T1
GB

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Riello RS 50 and is the answer not in the manual?

Riello RS 50 Specifications

General IconGeneral
Fuel TypeLight Oil
Burner TechnologyMonoblock
OperationTwo Stage
ControlElectronic
Air RegulationMechanical
Combustion HeadAdjustable
Electrical Supply230V / 50Hz

Summary

3 Safety and prevention

3.2 Personnel training

Specifies responsibilities and training requirements for personnel operating and maintaining the burner.

4 Technical description of the burner

4.4 Technical data

Provides detailed technical specifications including output, fuel, operating conditions, and noise levels for various burner models.

4.5 Electrical data

Details electrical requirements and specifications for different burner models, including supply voltage and power consumption.

4.8 Firing rates

4.10 Burner description

4.11 Control box RMG88...

4.12 Servomotor SQM..

5 Installation

5.1 Notes on safety for the installation

Crucial safety precautions and warnings to be observed before and during the burner installation process.

5.5 Preparing the boiler

5.7 Positioning the probe - electrode

5.8 Combustion head adjustment

5.9 Gas supply

5.9.3 Gas train installation

5.9.4 Gas pressure

5.10 Electrical connections

Notes on safety for the electrical wiring

Essential safety precautions for electrical wiring, including disconnections, earthing, and cable types.

5.11 Thermal relay adjustment (RS 38-50 THREE-PHASE)

6 Start-up, calibration and operation of the burner

6.1 Notes on safety for the first start-up

Safety guidelines and requirements for qualified personnel performing the initial burner start-up.

6.4 Burner ignition

6.5 Burner adjustment

6.5.3 Output in 1st stage

6.6 Pressure switch adjustment

6.6.1 Air pressure switch

Procedure for adjusting the air pressure switch to ensure correct operation and limit CO emissions.

6.6.2 Gas minimum pressure switch

Steps for adjusting the minimum gas pressure switch to prevent burner lockout due to low gas pressure.

6.7 Servomotor adjustment

6.8 Burner operation

6.8.3 Ignition failure

Details the conditions leading to ignition failure and subsequent lockout, including troubleshooting steps.

6.9 Burner start-up cycle diagnostics

6.9.1 Resetting of control box and diagnostics use

Instructions for using the control box diagnostics function to identify and reset malfunctions via LED indicators.

7 Maintenance

7.1 Notes on safety for the maintenance

Critical safety precautions for performing maintenance, including electrical disconnection and fuel shut-off.

7.3 Opening the burner

7.4 Closing the burner

8 Faults - Possible causes - Solutions

Related product manuals