Loading...
1541
6
GB
To remove the control-box from the burner, loosen screw (A)
(see figure below)
and pull towards
the arrow.
TESTING
Check the shut-down of the burner by opening the thermostats.
RUN OF THE ELECTRICAL CABLE
1 - Cable gland
2 - Cable-clamp
3 - Terminal block
N - Neutral
L - Phase
- Burner-earth
- Lock-out lamp
The photoresistance is fitted directly
into the control-box
(underneath the
ignition-transformer)
on a plug-in sup-
port.
Ignition
transformer
Photoresistance
S7057
S7058