ELECTRICAL WIRING
Brown
White (50V)
Blue
Motor
Capacitor
Regulating thermostat
Neutral
Switch with fuse
6A max.
N L
M
~
S7026
Black
NOTES
Wires of 1 mm
2
section.
The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
To remove the control-box from the burner,
loosen screw (A) (see figure) and pull towards
the arrow.
The photoresistance is fitted directly into the
control-box (underneath the ignition-trans-
former) on a plug-in support.
TESTING
Check the shut-down of the burner by opening the
thermostats.
CARRIED-OUT IN THE FACTORY
WARNING
Do not exchange the neutral with the phase.
230V ~ 50Hz
NL
Limit thermostat
with manual resetting
Remote lock-out lamp
(230V - 0.5A max.), if required
123456789
Blue
Brown
Terminal block of
control-box 530SE
*
Valve
T
T
RUN OF THE ELECTRICAL CABLE
1 - GrommetN - Neutral
2 - Cable-clampL - Phase
3 - Terminal block - Burner-earth
A321
D5228
Black