RIGOL
DS1000Z-E Performance Verification Guide
II
Safety Requirement
General Safety Summary
Please review the following safety precautions carefully before putting the instrument into operation
so as to avoid any personal injury or damage to the instrument and any product connected to it. To
prevent potential hazards, please follow the instructions specified in this manual to use the instrument
properly.
Use Proper Power Cord.
Only the exclusive power cord designed for the instrument and authorized for use within the local
country could be used.
Ground the Instrument.
The instrument is grounded through the Protective Earth lead of the power cord. To avoid electric
shock, connect the earth terminal of the power cord to the Protective Earth terminal before connecting
any input or output terminals.
Connect the Probe Correctly.
If a probe is used, the probe ground lead must be connected to earth ground. Do not connect the
ground lead to high voltage. Improper way of connection could result in dangerous voltages being
present on the connectors, controls or other surfaces of the oscilloscope and probes, which will cause
potential hazards for operators.
Observe All Terminal Ratings.
To avoid fire or shock hazard, observe all ratings and markers on the instrument and check your
manual for more information about ratings before connecting the instrument.
Use Proper Overvoltage Protection.
Ensure that no overvoltage (such as that caused by a bolt of lightning) can reach the product.
Otherwise, the operator might be exposed to the danger of an electric shock.
Do Not Operate Without Covers.
Do not operate the instrument with covers or panels removed.
Do Not Insert Objects Into the Air Outlet.
Do not insert anything into the holes of the fan to avoid damaging the instrument.
Use Proper Fuse.
Please use the specified fuses.
Avoid Circuit or Wire Exposure.
Do not touch exposed junctions and components when the unit is powered on.
Do Not Operate With Suspected Failures.
If you suspect that any damage may occur to the instrument, have it inspected by RIGOL authorized
personnel before further operations. Any maintenance, adjustment or replacement especially to
circuits or accessories must be performed by RIGOL authorized personnel.
Provide Adequate Ventilation.
Inadequate ventilation may cause an increase of temperature in the instrument, which would cause
damage to the instrument. So please keep the instrument well ventilated and inspect the air outlet and
the fan regularly.

Other manuals for Rigol DS1202Z-E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1202Z-E and is the answer not in the manual?

Rigol DS1202Z-E Specifications

General IconGeneral
TypeTabletop
Product typeDigital sampling oscilloscope
Bandwidth200 MHz
Sampling rate500 MS/s
Frequency range0 - 0.001 MHz
Channels quantity2 channels
Vertical resolution8 bit
Minimum time base setting (per division)4 ns
Minimum vertical sensitivity (per division)1 mV
Display typeLCD
Display diagonal7 \
Display resolution800 x 480 pixels
AC input voltage100 - 240 V
AC input frequency45 - 440 Hz
Power consumption (max)50 W
Operating temperature (T-T)0 - 50 °C
Package weight3500 g
Weight and Dimensions IconWeight and Dimensions
Depth122.4 mm
Width313.1 mm
Height160.8 mm
Weight2900 g