Programming Introduction RIGOL
Programming Guide for DS1000CA Series
2-59
Command Format:
:MEASure:RISetime? [<source>]
Function Explanation:
This command is used to query the rise time of the waveform. The options of
<source> are CHANnel1 or CHANnel2.
Returned Format:
Such as 3.10e-04, the unit is s.
14. :MEASure:FALLtime?
Command Format:
:MEASure:FALLtime? [<source>]
Function Explanation:
This command is used to query the fall time of the waveform. The options of
<source> are CHANnel1 or CHANnel2.
Returned Format:
Such as 3.10e-04, the unit is s.
15. :MEASure:PERiod?
Command Format:
:MEASure:PERiod? [<source>]
Function Explanation:
This command is used to query the waveform period. The options of
<source> are CHANnel1 or CHANnel2.
Returned Format:
Such as 1.00e-03, the unit is s.
16. :MEASure:PWIDth?