Cause Check Points Refer to
page
Does not operate when "Heating"
button is pressed.
(ON/Combustion indicator does not
illuminate green.)
• Is the power point inserted into the power point securely?
• Have any household fuses melted or breakers cut off?
• Has there been a power failure?
• Is the Lock set?
86
-
-
89
Does not ignite. (ON/Combustion
indicator does not illuminate red.)
• Is the room gas valve completely open?
• Is there any air remaining in the gas pipes (strengthened gas hose)?
• Is the micro-computer meter activated?
87
87
ø1
The flame goes out during use.
• Is there any dust blocking the air filter? (Is the filter indicator flashing?)
• Is the air outlet being blocked?
• Is the micro-computer meter activated?
90
86
ø1
Does not warm sufficiently.
• Is the room temperature set too low?
• Are any windows or doors in the room open?
• Is the room gas valve completely open?
• Are there any objects placed within 60cm of the front of the unit?
87
-
87
86
Heater
There is a gas odour
• Is the strengthened gas hose connected properly?
• Is the strengthened gas hose damaged?
87
87
Does not operate when "Purif"
button is pressed.
(Dust indicator does not illuminate
green. Fan does not rotate.)
• Is the power point inserted into the power point securely?
• Have any household fuses melted or breakers cut off?
• Has there been a power failure?
• Has the Primary Filter come loose?
• Is the Child Lock set?
-
-
-
25
12
The dust indicator stays red and
does not change.
• Is the air dirty?
The dust indicator does not
illuminate red, even when taking in
smoke.
• Change the location of the unit. Or, turn the "Boost" operation ON.
• Is the unit installed in a room that has a greater volume than specified for
the unit?
• Is the dust sensor dirty?
20
30
27
Air Purifier
Does not pick up odours and smoke,
etc. well.
The unit becomes very noisy.
• Is the filter cartridge dirty?
(Clean the filter cartridge. If there is no change, then replace the filter
cartridge with a new filter.)
25