Rinnai 15 Slim Four-Way Cassette OM
TROUBLESHOOTING TIPS
When troubles occur, please check the following points before contacting a qualied service technician.
PROBLEM POSSIBLE CAUSES SOLUTION
The unit is not
working
Power Failure Wait for the power to be restored
The power switch is o󰀨 Turn on the power
The fuse is burned out Replace the fuse
Remote control batteries are dead Replace the remote control batteries
The unit's 3-minute protection has been activated Wait 3-minutes after restarting the unit
Poor cooling
performance
Temperature setting may be higher than the ambient
room temperature
Lower the temperature setting
The heat exchanger on the indoor or outdoor unit is
dirty
Contact qualied service technician to
clean the a󰀨ected heat exchanger
The air lter is dirty Remove the lter and clean it according to
instructions
The air inlet or outlet of either unit is blocked Turn the unit o󰀨, remove the obstruction
and turn it back on
Doors and windows are open Make sure that all doors and windows are
closed while operating the unit
Excessive heat is generated by sunlight Close windows and curtains during periods
of high heat or bright sunshine
Low refrigerant due to leak or long-term use Contact qualied service technician to
check for leaks and recharge the system
with refrigerant
The unit starts
and stops
frequently
There's too much or too little refrigerant in the system
There is air, incompressible gas or foreign material in
the refrigerant system
Contact a qualied service technician
to evacuate & recharge the system with
refrigerant
System circuit is blocked Contact a qualied service technician to
determine which circuit is blocked, replace
the malfunctioning piece of equipment�
The compressor is broken Contact a qualied service technician to
replace the compressor
The voltage is too high or too low Contact a qualied service technician to
install a voltage regulator
Poor heating
performance
The outdoor temperature is lower than 7°C Contact qualied service technician to
check for leaks & recharge the system�
Cold air is entering through doors and windows Make sure that all doors and windows are
closed during use
Low refrigerant due to leak or long-term use Contact qualied service technician to
check for leaks, re-seal if necessary top o󰀨
refrigerant
TROUBLESHOOTING TIPS FOR GRILL
CAUTION
DO NOT ATTEMPT TO REPAIR THE UNIT YOURSELF
A QUALIFIED SERVICE TECHNICIAN SHOULD CHECK THAT THE DROP HANGER IS HUNG PROPERLY,
TO ENSURE THAT THE UNIT GRILL DOES NOT FALL OFF WHEN HUNG WITH THE SUSPENSION WIRE.
PROBLEM POSSIBLE CAUSES
The electrical motor gives forth a sound even though the
grill is in the panel
The electrical motor has been ON continuous for a while,
and the suspension wire has become loose�
The grill moves up and down two times when inserted
into the panel
Make sure that the grill is properly inserted into panel�
A psss��� sound can be heard when the unit is ON and
also when the unit is turned OFF
The fuse may be burnt out, due to extreme temperature
changes�
TROUBLE SHOOTING

Other manuals for Rinnai CIN070R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai CIN070R and is the answer not in the manual?

Rinnai CIN070R Specifications

General IconGeneral
BrandRinnai
ModelCIN070R
CategoryAir Conditioner
LanguageEnglish

Related product manuals