REU-2532FFU Series 15 Rinnai
Safety devices
Appliance - AC 120 Volts - 60Hz.
Remote control DC 12 Volts (Digital)
Flame failure - Flame rod
Boiling protection - 203°F
Remaining flame (OHS) 194°F bi-metal switch
Thermal fuse 26F
Automatic frost protection - Bi metal sensor & anti-frost heaters
Combustion fan rpm check - Integrated circuit
Over current - Glass fuse (3 amp)
If remote fails or becomes disconnected unit defaults to 100°F with water
flowing, this is an anti-scald feature.
Remote control cable Non-polarized two core cable or low voltage thermostat wire
Clearances from combustibles
Top of heater 6"
Front of heater 6"
Sides of heater 2"
Back of heater 0"
Floor 12"
Vent/Air Intake 0"
Minimum and Maximum gas supply pressure
Natural Gas : *Minimum 6" W. C.
(NAT.) **Maximum 10.5" W. C.
Propane Gas: *Minimum 10" W. C.
(LPG) **Maximum 14" W. C.
Manifold Gas Pressure
Natural Gas 3.7" W. C. high fire 0.77" W. C. low fire
LPG: 4.2" W. C. high fire 0.93" W. C. low fire
Warranty
2532FFU: Ten years heat exchanger / five years parts (see unit's warranty for details)
2532FFU(C): Five years heat exchanger and parts (see unit's warranty for details)
*Minimum input pressure is for the purpose of input adjustments.
**Do not exceed maximum pressure.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai Continuum Series and is the answer not in the manual?

Rinnai Continuum Series Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Maximum Water Pressure150 PSI
InstallationIndoor or Outdoor
Maximum BTU Input199, 000 BTU/hr
Electrical Requirements120V
Warranty5 years parts, 1 year labor

Related product manuals