19. Diagnostic Points
Flow Chart is on page #28
Wiring Diagram is on page #35
tnenopmoC
tnioPtnemerusaeM
eulaVlamroNsetoN
.oN.pmoCroloCeriW
rotcetorPegruSF
7
nworB-eulBV231-801CA
eciveDlortnoCwolFretaWB
2
eulB-deRV31-11CDtinUotdeilppuSrewoP
egnarO-yarGV31-11CDtinUotdeilppuSrewoP
wolleY-yarG
)nOretimiL(V1CDwoleB
n
oitisoPnepOlluF
)ffOretimiL(V6-4CD
nworB-yarG
)nOretimiL(V1CDwoleB
noitisoPesolClluF
)ffOretimiL(V6-4CD
eci
veDlortnoCwolFssap-yBG
1
etihW-nworB
etihW-egnarO
etihW-wolleY
dnGetihW-deR
V6-2CDedoMgnitarepOnItinU
k53-51
lortnoCetomeRD
1
kcalB-kcalBV31-11CD
rosneSwolFretaWB
4
kcalB-deRV31-11CD
)zH03(nim/lag28.0nO
nim/eslup0081revO
)zH02(nim/lag6.0ffO
nim/eslup0021woleB
dnGkcalB-wol
leY)zH064-71esluP(V7-4CD
naFnoitsubmoCA
1
kcalB-deRV54-6CD
kcalB-wolleYV31-11CD
dnGkcalB-etihW)zH004-33(V54-6CD
doRemalFC
1
dnG-wolleYV051-5CAnoitingIretfA
doRemalF-wolleY1CDrevO µAnoitidnoCemalF
evlaVgnitaludoMC
2
kniP-kniP
V51-2CD
18-76
rotsimrehTgniogtuO
regnahcxEtaeH
retsimrehTgniogtuO
B
5
B
6
etihW-etihW
KO.41-4.11F°95
K8.7-4.6F°68
K5.4-6.3F°311
K7.2-2.2F°041
K8.0-6.0F°122
rotsimrehTriAB
1
etihW-etihW
esuFlamrehT
B
3
C
3
deR-deR1woleB
rotingIF
8
yarG-yarGV011-09CA
evlaVdioneloSniaME
1
kcalB-kniP
V001-08CD
K1.2-7.1
1evlaVdioneloSE
2
kcalB-wolleY
V001-08CD
K1.2-7.1
2evlaVdioneloSE
3
kcalB-eulB
V001-08CD
K1.2-7.1
3evlaVdioneloSE
4
kcalB-nworB
V001-08CD
K0.2-7.1
SECNATSISERDNASEGATLOVREMROFSNART
sgnidniWyramirPF
7
nworB-eulB36-15
sgnidniWyradnoceSF
9
kcalB-etihWV011-09CA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai Continuum Series and is the answer not in the manual?

Rinnai Continuum Series Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Maximum Water Pressure150 PSI
InstallationIndoor or Outdoor
Maximum BTU Input199, 000 BTU/hr
Electrical Requirements120V
Warranty5 years parts, 1 year labor

Related product manuals