EasyManua.ls Logo

Rinnai Continuum REU2532-W Series User Manual

Rinnai Continuum REU2532-W Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Continuum and Integrity
REU2532-W and REU2532-WC
Series Water Heaters
SERVICE MANUAL
Rinnai Corporation
103 International Drive
Peachtree City, Ga. 30269
Telephone number (800)621-9419
No portion or part of this manual may be copied without prior permission from Rinnai Corporation.
Question and Answer IconNeed help?

Do you have a question about the Rinnai Continuum REU2532-W Series and is the answer not in the manual?

Rinnai Continuum REU2532-W Series Specifications

General IconGeneral
BrandRinnai
ModelContinuum REU2532-W Series
CategoryWater Heater
LanguageEnglish

Summary

Features

Safety Features

Micro-computer controlled safety devices and automatic anti-frost protection.

Installation

Safety Devices

Flame Failure Safety

Monitors flame intensity and compares it to feedback signals; shuts off unit if incorrect.

Over Heat Protection Device

Shuts off gas supply if heat exchanger reaches 194°F.

No Water Safety

Prevents gas flow if water flow sensor stops sending magnetic pulses.

Thermal Fuse Safety

Breaks circuit to shut off power if heat exchanger reaches 264°F.

Combustion Fan Revolution Check

Monitors fan RPMs; adjusts speed or shuts down unit if deviation occurs.

Automatic Frost Protection

Activates anti-frost heaters below 37°F and can fire for 3 seconds to prevent freezing.

5°F Over Temperature Cut-Off

Dip Switches

Dip Switch Default Settings

Operation Flow Principle

Operation Principles

Error Codes and Remedies

Error Code 10: Air Supply or Exhaust Blockage

Check intake/exhaust ports, clearances, gas supply, and wiring.

Error Code 11: No Ignition

Verify gas supply, pressure, dip switches, and igniter operation.

Error Code 12: Flame Failure

Check flame rod, gas valve, power supply, and MSA controls.

Error Code 14: Thermo Fuse

Check dip switches, manifold pressure, gas type, and heat exchanger.

Error Code 16: Over Temperature Warning

Check heat exchanger, air flow, circulating system, and foreign materials.

Error Code 32: Outgoing Water Temperature Sensor Faulty

Check sensor wiring, resistance, and scale; replace sensor if faulty.

Error Code 33: Heat Exchanger Temperature Sensor Faulty

Check sensor wiring, resistance, and scale; replace sensor if faulty.

Error Code 34: Combustion Air Temperature Sensor Faulty

Check sensor wiring, fan blade, air flow; replace sensor if faulty.

Error Code 52: Modulating Solenoid Valve Abnormal

Check solenoid valve wiring, harness, and terminals; ohm out valve.

Error Code 61: Combustion Fan Failure

Check fan motor turning freely, wiring harness, and connections.

Error Code 71: Solenoid Valve Circuit Faulty

Check wiring harness to solenoids and ohm out each solenoid.

Error Code 72: Flame Sensing Device Faulty

Check micro amps, clean flame rod, check for obstructions, check wiring.

Error Code LC: Scale Build-up in Heat Exchanger

Turn off/on power; flush heat exchanger; replace heat exchanger.

No Code: No Water Flow Activation

Check filter, minimum flow rate, pipe dope, crossed lines, bleed over.

Diagnostic Points

Wiring Diagram

Block Diagram

Electrical Component Analysis

Fuse Check

Locates fuses and provides steps to check for blown fuses.

Main Transformer Check

Measures voltage and resistance of the main transformer.

Remote Control Check

Checks voltage at remote control terminals to diagnose issues.

Water Flow Sensor Check

Measures voltage at PCB connector for the water flow sensor.

Thermal Fuse Check

Combustion Flame Failure Troubleshooting

Unable to Adjust Hot Water Temperature

Anti-Frost Heater Operation Check

Electrical Component Analysis Summary

Combustion Flame Failure

Troubleshoots flame failure by checking flame rod, ground wire, and bracket.

Cannot Adjust Water Temperature

Troubleshoots temperature adjustment issues with thermistor, solenoids, valve, and servo.

Anti-Frost Heater Not Working

Checks anti-frost heaters and frost sensor switch for proper operation.

Gas Pressure Setting Procedure

Dismantling for Service

Serviceman's Troubleshooting Information