EasyManuals Logo

Rinnai Continuum Series User Manual

Rinnai Continuum Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
REU-2532FFU Series 20 Rinnai
(Switches 3,4, & 5) Temperature Adjustment Switches. Switches #3, 4, and 5 are used to set fixed temperatures with or
without the remote keypads. Contact Rinnai for dip switch settings when changing the unit’s PC board or setting up special
applications. Failure to set dip switches to the proper position will result in damage to the unit, property damage, personal
injury or death. DO NOT, adjust switches unless you have written permission directly from Rinnai. Call 1(800)621-9419 to
set-up a special training class pertaining to dip switch functions.
(Switch #6) Flow Switch and Temperature Adjustments. Rinnai offers a flow switch that can serve as an anti-scald
device. This switch is installed in-line with each bathroom. Therefore, if someone was using water above 120°F and a tap
was turned on in one of the bathrooms, the unit would automatically default back to 120°F to prevent scalding. When dip
switch #6 is set to the “ON” position this function is activated. At the present time this switch is not used in the U.S.
market, due to anti-scald devices and/or pressure balancing valves presently being used in our market.
(Switches 7& 8) Low/High Fire Combustion Control Switches. Dip switch # 7 is used to place the unit into forced low
fire when checking and/or setting manifold gas pressures. Dip switch #7 and #8 are used to place the appliance into forced
high fire. Before making any adjustments to these switches, please ensure you follow the gas pressure setting procedure
found in this manual.
“SW2” row of Dip Switches
1. Gas type (Used only when replacing PCB or converting unit)
2. Lime control switch activated or de-activated.
3. Plus three degrees or plus six degrees differential.
4. Type of unit. (Residential or commercial)
(SW2) Explanation of “SW2” row of Dip Switches
(Switch #1) Gas Type Switch. When set to the “OFF” position the unit is setup to operate on propane gas, in the “ON”
position it is setup for natural gas.
(Switch #2) Lime Control Switch. Set dip switch #2 to the “OFF” position to activate the lime control function. To
deactivate this function place this switch in the “ON” position.
(#3) Temperature Differential Switch. The temperature of the outgoing water is constantly monitored by the outlet
temperature thermistor. If the outlet water temperature rises to more than 5.4°F above the preset temperature, the burner
will automatically go out when dip switch #3 is in the “OFF” position. The burner will ignite again once the outlet water
temperature falls below the preset temperature. If this switch is set to the “ON” position it will allow a 10.8 °F rise.
(Switch #4) Type of Unit. Danger; do not adjust this dip switch. Adjusting this switch will result in damage to the unit,
property damage, personal injury, or death.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai Continuum Series and is the answer not in the manual?

Rinnai Continuum Series Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Maximum Water Pressure150 PSI
InstallationIndoor or Outdoor
Maximum BTU Input199, 000 BTU/hr
Electrical Requirements120V
Warranty5 years parts, 1 year labor

Related product manuals