EasyManua.ls Logo

Rinnai E32S - Technical Specifications

Rinnai E32S
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation & Servicing Instructions E-Range
33
15 Technical specifications
Technical specifications Table 9
Boiler type E32S
Input Hs CH kW 32
Q
n
Output Hi CH
kW 28.8
Efficiency class according BED 
Efficiency according EN677
(36/30°C part load. Hi)
% 109.9
Efficiency according EN677
(80/60°C full load. Hi)
% 97.9
Modulation range CH
(capacity 80/60°C)
kW 6.1 - 28.2
Modulation range CH
(capacity 50/30°C)
kW 6.8 - 30.6
Nox class EN483 5
CO
2
%9
Temperature class for PP flue T100
Appliance type C13 C43 C53 C63 C83
Flue gas temp. CH
(80/60°C on full load)
°C 68
Flue gas temp. CH
(50/30°C on low load)
°C 31
Categories II2L3P
Gas consumption G20 CH (DHW)
(at 1013 mbar/15°C)
m
3
/h
3.05
Electr. power consumption max. W 145
Electr. power consumption stand by W 10
Current V/Hz 230/50
Fuse rating A 5
Degree of protection acc. EN 60529 IPX4D
Weight (empty) kg 40
Width mm 500
Height mm 870
Depth mm 395
Water content CH l 5
After run time pump CH min 19
After run time pump DHW min
P
MS
Water pressure min./max.
bar 1/3
Flow temperature max. °C 85
Pump type UP20-60
Available pump height CH kPa 17
CE product identification number(PIN) 0063BR3409