SPECIFICATION
Type of appliance
Exhaust system
Rinnai Australia model
N“
Installation
Operation
Dimensions
Temperature controlled continuous gas hot water system.
Forced combustion.
REU-24W-A
Externally mounted.
Remote control, mounted in kitchen and/or bathroom.
Width
-
370 mm.
Height
-
538 mm.
Death
-
210 mm. I With bracket and flue extension
]
Weight
20 kilograms.
I
I
Connections
Ignition system
Gas consumption
Electrical consumption
Hot water capacity
Temperature range
Water flow control
Minimum operating pressure
Normal operating pressure
Minimum operating water flow
Power supply
Safety devices
Gas supply
-
R
W
l2OA.
Cold water supply
-
R
%
l20A.
Hot water supply
-
R
3k
l20A.
Direct electronic ignition.
Natural gas
-
185 MI/h HI, 21
Ml/h
LOW.
Normal
-
72 Watts.
Standby
-
8 Watts.
Automatic frost protection
-
144Watts.
2.2 to 24
L/min .
[ Raised
25°C
]
35°C to 75°C in 16 steps.
Electronic water flow control device.
15
kPa.
70 to 830 kPa.
2.5 L/min.
Appliance
- 2301240 Volts 50 I-Ix.
Remote control
-
DC 12 Volts Digital.
Flame failure
-
Flame
rod.
Remaining flame [OHS]
-
200°C
bi-metal switch.
Boiling protection
-
105°C lockout thermistor.
Fusible link
-
152°C thermal fuse.
Burner light back
_
135°C bi-metal switch.
Pressure relief valve
-
Gpen s
-
1400
kPa.
-
Closes
-
1000 kPa.
Automatic frost protection
-
Bi-metal sensor
&
anti-frost heaters.
Combustion fan rpm check
-
Integrated circuit system.
I