COMBUSTION SPECIFICATION
The
FUXJ-24
W-A
is only approved for use on Natural gas.
Consumption
Input
Orifice A Orifice B
Gas type selection switch positions *
P=W
FzThl
[=I
b4
4WOo
185
05.0
05.2
1
2
3
4
5
OFF ON OFF OFF OFF
* Down position = ON, Up position =
OFF. See page 34 for further details.
Test Point Pressure Modulating valve
Fanspeed
Fpal
current
[mA]
HZ
Maximum
0.70
158
f
5
128
f
2
Minimum
0.04
55
f
5
67.5
f
2
I
I I
I
4
SCHEMATIC DIAGRAM
THERMAL
FUSE
REMAINING FLAME
SAFETY DEVICE
ELECTRODE
FLAME ROD,
SPARK GENERATOR-
HEAT EXCHANGER
THERMISTOR
(OHS)-
REV
COUNTER-
ANTI-FROST
/
PROTECTION HEATER
HEAT EXCHANGER
ELECTRODE
AIR GAS RATIO
THERMOCOUPLE
COMBUSTION FAN
BY-PASS CONTROL
DISTRIBUTOR
-
PRESSURE RELIEF
VALVE
\
MODULATING
SOLENOID
SOLENOID VAL
CHANGE-OVER
SOLENOID
i
I
c__.
;
7
ELECTRICAL
CONNECTION
4
HOT WATER SUPPLY
OUTLET THERMISTOR
VE
ELECTRONIC WATER FLOW
CONTROL DEVICE
-WATER FILTER
REMOTE CONTROL
HOT WATER OUTLET
GAS SUPPLY
U
CONNECTION
WATER INLET
CONNECTION