EasyManua.ls Logo

Rinnai REU-A1620WB - User Manual

Rinnai REU-A1620WB
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Gas Continuous Flow Water Heater
Operation & Installation Manual
MODELS
Infinity 32 (REU-AM3237W)
HD32e (REU-AM3237WC)
Infinity 26 Touch (REU-AM2626WDL)
Infinity 26 (REU-AM2626WD)
Infinity 20 (REU-AM2024WD)
Infinity 16 (REU-AM1620WD)
Infinity 12 (REU-AM1220WD)
Infinity Enviro 26 (REU-E2626W)
Infinity Enviro 16 (REU-E1620W)
Infinity 28i (REU-VCM2837FF)
HD28i (REU-VCM2837FFC)
HD28e (REU-VCM2837WC)
B26 (REU-A2626WB)
B20 (REU-A2024WB)
B16 (REU-A1620WB)

Table of Contents

Questions and Answers

Summary

Warnings & Important Information

Before Using This Appliance

Read the manual thoroughly for safe and correct use of the appliance.

Warning About Hot Water

Hazards of scalding water, especially for vulnerable groups.

Operational Safety Information

Guidelines for safe operation, including child supervision and appliance handling.

Water Temperature Control

Maximum Delivery Temperatures

Factory pre-set temperatures and authorized adjustments for max delivery temp.

Temperature Control

User control of hot water temperature and priority settings for multiple controllers.

Universal Water Controller (MC-601 Q) Operation

Step-by-step guide to operating the MC-601Q universal water controller.

Turning On

Instructions on how to power on the water controller.

Adjusting Temperature

How to select and adjust the desired water temperature.

Smartstart Pre-Heat System

Explanation and operation of the Smartstart pre-heat function for faster hot water.

Preheat Function

Details on how the preheat function works.

Preheat Operation

Step-by-step guide for activating and using the preheat function.

Trouble Shooting

Error Codes

List of error codes with descriptions and potential remedies for faults.

Troubleshooting Without Water Controllers

Resolving issues when the appliance is operated without any water controllers.

Service

Information on authorized service and repair by qualified personnel.

General Installation Information

Appliance Location

Guidelines for selecting the optimal placement of the water heater.

Hot Water Delivery Temperature

Managing hot water delivery temperature, including 50°C compliance.

Flueing

Appliance Flue Terminal

Requirements for the location and clearances of the appliance flue terminal.

REU-E Model Neutraliser Tank & Drain

Important Considerations for Neutraliser Drain Pipe

Critical factors for the correct installation of the neutraliser drain pipe.

Water Controller Installation

Master; Sub Water Controllers & Associated Temperatures

Designating master/sub controllers and their temperature limits.

Universal Water Controller (MC-601 Q) Installation

Detailed instructions for the physical installation of the MC-601Q controller.

Commissioning

Testing

Pre-connection checks and operational tests required before final commissioning.

Delivery Temperature

Verifying and adjusting hot water delivery temperatures after installation.

Summary

Warnings & Important Information

Before Using This Appliance

Read the manual thoroughly for safe and correct use of the appliance.

Warning About Hot Water

Hazards of scalding water, especially for vulnerable groups.

Operational Safety Information

Guidelines for safe operation, including child supervision and appliance handling.

Water Temperature Control

Maximum Delivery Temperatures

Factory pre-set temperatures and authorized adjustments for max delivery temp.

Temperature Control

User control of hot water temperature and priority settings for multiple controllers.

Universal Water Controller (MC-601 Q) Operation

Step-by-step guide to operating the MC-601Q universal water controller.

Turning On

Instructions on how to power on the water controller.

Adjusting Temperature

How to select and adjust the desired water temperature.

Smartstart Pre-Heat System

Explanation and operation of the Smartstart pre-heat function for faster hot water.

Preheat Function

Details on how the preheat function works.

Preheat Operation

Step-by-step guide for activating and using the preheat function.

Trouble Shooting

Error Codes

List of error codes with descriptions and potential remedies for faults.

Troubleshooting Without Water Controllers

Resolving issues when the appliance is operated without any water controllers.

Service

Information on authorized service and repair by qualified personnel.

General Installation Information

Appliance Location

Guidelines for selecting the optimal placement of the water heater.

Hot Water Delivery Temperature

Managing hot water delivery temperature, including 50°C compliance.

Flueing

Appliance Flue Terminal

Requirements for the location and clearances of the appliance flue terminal.

REU-E Model Neutraliser Tank & Drain

Important Considerations for Neutraliser Drain Pipe

Critical factors for the correct installation of the neutraliser drain pipe.

Water Controller Installation

Master; Sub Water Controllers & Associated Temperatures

Designating master/sub controllers and their temperature limits.

Universal Water Controller (MC-601 Q) Installation

Detailed instructions for the physical installation of the MC-601Q controller.

Commissioning

Testing

Pre-connection checks and operational tests required before final commissioning.

Delivery Temperature

Verifying and adjusting hot water delivery temperatures after installation.

Rinnai REU-A1620WB Specifications

General IconGeneral
CategoryWater Heater
ModelREU-A1620WB
TypeTankless
Fuel TypeGas
Gas TypeNatural Gas
Heating Capacity160, 000 BTU/h
Temperature Range98°F - 140°F
Energy Efficiency0.82 Energy Factor
Flow Rate6.6 GPM
Energy Factor0.82
Maximum BTU160, 000 BTU/h
Ignition TypeElectronic
Warranty12 years heat exchanger, 5 years parts, 1 year labor