Page #10 background image
10 Value Series Manual
Unit clearances
* 0 inches from vent components and condensate
drain line.
The clearance for servicing is 24 inches in front of the
water heater.
For closet installaon, clearance is 6 inches (152 mm)
from the front.
Indoor models: V75i, V65i
Outdoor models: V75e, V65e
The clearance for servicing is 24 inches in front of the
water heater.
to Combusbles
inches (mm)
to Non-
Combusbles
inches (mm)
Top of Heater 12 (305) 2 (51)
Back of Heater 0 (zero) 0 (zero)
Front (Panel) 24 (610) 0 (zero)
Front (Exhaust) 24 (610) 24 (610)
Sides of Heater 6 (152) 1/8 (3.2)
Ground/Boom 12 (305) 2 (51)
to Combusbles
inches (mm)
to Non-
Combusbles
inches (mm)
Top of Heater 6 * (152) 2 *(51)
Back of Heater 0 (zero) 0 (zero)
Front of Heater 6 (152) 6 (152)
Sides of Heater 2 (51) 1/2 (13)
Ground/Boom 12 (305) 12 (305)
Vent 0 (zero) 0 (zero)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai V75i series and is the answer not in the manual?

Rinnai V75i series Specifications

General IconGeneral
TypeTankless Water Heater
Fuel TypeNatural Gas or Propane
Maximum BTU180, 000 BTU
Flow Rate7.5 GPM
Energy Factor0.82
InstallationIndoor
Gas Connection3/4" NPT
Water Connection3/4" NPT
BTU Input Range15, 000 - 180, 000 BTU
Temperature Range98°F to 140°F
Electrical Requirements120V AC, 60Hz
Ignition TypeElectronic
Warranty5-year on parts, 1-year on labor