The “Simple Operation” connection can then be used to tare the indicator. Set SimpleOp Command Out to 2
(from the simple operations table in Section 20.3.3) to perform the tare. Displayed Weight is now 0 and the
Status Bit NET is set.
To switch back to gross weight, first set the SimpleOp Command Out to 0. Then set SimpleOp Command Out to
4 to toggle gross/net. Displayed Weight is now 1500 and the Status Bit NET is not set.
117 C500-600-2.0.3