Name Address Type R W Description
Setpoint 4 type A461
H
uint8 A A Set setpoint 4 type:
0 is off
1 is on
2 is over
3 is under
4 is centre of zero
5 is zero band
6 is net
7 is motion
8 is error
9 is buzzer
10 is weigh out
11 is weigh in.
Setpoint 4 lock A462
H
uint8 A A Set setpoint 4 lock:
0 is off
1 is on.
Setpoint 4 logic A463
H
uint8 A A Set setpoint 4 logic:
0 is high
1 is low.
Setpoint 4 alarm A464
H
uint8 A A Set setpoint 4 alarm:
0 is none
1 is single beep
2 is double beep
3 is continuous beeping
4 is flash the display.
Setpoint 4 source A466
H
uint8 A A Set setpoint 4 source:
0 is gross weight
1 is net weight.
Setpoint 4 Target A468
H
int32 A A Set setpoint 4 target.
Setpoint 4 Hysteresis A469
H
int32 A A Set setpoint 4 hysteresis.
Setpoint 4 in flight A46A
H
int32 A A Set setpoint 4 in flight.
Setpoint 4 Timing A470
H
uint8 A A Setpoint 4 timing:
0 is level
1 is edge
2 is latch
3 is pulse.
Setpoint 4 Reset A471
H
uint8 A A Setpoint 4 rest:
0 is none
1 is reset A
2 is reset B.
Setpoint 5 type A481
H
uint8 A A Set setpoint 5 type:
0 is off
1 is on
2 is over
3 is under
4 is centre of zero
5 is zero band
6 is net
7 is motion
8 is error
9 is buzzer
10 is weigh out
11 is weigh in.
90 C500-600-2.0.3