Rinstrum - R300 Series Digital Indicator Operator Manual Rev 1.5
Page 13
5. Special Functions (R320 Only)
5.1. Testing the Display
• Press the <TEST> key to clear the display then
show all segments of the display then clear the
display again before returning to normal operation.
Note: This feature is also available on the R310. For more
information refer to TEST key page 10.
5.2. Counting
• Place the container on the weigh platform and
press <TARE> if required.
• Place the sample pieces to be counted on the weigh
platform.
• Press and hold the <COUNT> key for two
seconds. The default number of pieces in the
sample will be displayed.
• Use the <GROSS/NET> and
<PRINT> keys to alter the
number of pieces.
and
• Press <COUNT>. The current sample will be
stored against the entered pieces. The letter p (for
pieces) displays when in counts display.
• Press the <COUNT> key to toggle between the weight
display and the counts display.
• If printing is enabled the sample quantity and weight will be
printed.